HYDRODIGIT-S1

Single jet, digital display with 8 digits Inductive transmission.
Produced in the versions for cold water and hot water in the diameters DN15 and DN20
mm (1/2"- 3/4"). 360° rotating dial.
Wireless M-BUS OMS or LoRa integrated transmission modules and upon request NB-IoT.

TECHNISCHE EIGENSCHAFTEN

15 (1/2”)20 (3/4”)
Overload flow rate Q4m³/h3,1255
Permanent flow rate Q3m³/h2,54
R=400 H ↑Transitional flow rate Q2L/h1016
R=400 H ↑Minimum flow rate Q1L/h6,2510
R=250 H ↑Transitional flow rate Q2L/h1625,6
R=250 H ↑Minimum flow rate Q1L/h1016
R=160V H ↓ →Transitional flow rate Q2L/h2540
R=160V H ↓ →Minimum flow rate Q1L/h15,62525
Starting flowL/h33
Maximum reading99.99999.999
Maximum admissible pressure MAPbar1616

Available also Q3 1,6

BASIS-VERSION

  • R250-H ↑ and R160-V H ↓ → versions
  • For cold 0,1-50° C and hot water 30-90°C
  • Turbine reading through inductive system
  • Direct reading on 8 digits LCD display
  • IP68
  • Battery life 10+ years
  • Consumptions historical archive
  • Alarms (Reverse flow, losses...)
  • 360° rotating digital dial
  • Impossible to fraud magnetically
  • Integrated communication modules WMBUS or LORA
  • Connectable to a PC via IR IEC 62056-21 probe

MONTAGEPOSITION

AUF ANFRAGE

  • Equipped with NB-IoT module
  • R400-H ↑ and R160-V H ↓ → versions
  • R160 version
  • Lid

GEWICHT UND DIMENSION

DN15 (1/2”)15 (1/2”)20 (3/4”)15 (1/2”)15 (1/2”)20 (3/4”)
Lmm80110130145165190
Imm160190228225245288
Hmm777477747477
hmm131417141417
Bmm818181818181
D Threadingin3/4”3/4”1”3/4”3/4”1"
Weight with unionsKg0,650,700,850,550,560,70
Weight without unionsKg0,500,550,600,400,410,45

Threading - EN ISO 228-1:2003