MAG-C

Electromagnetic flowmeter for measuring the volume and the flow of electrically conductive liquids.

The absence of internal moving components guarantees maximum measurement accuracy, no maintenance requirement, constant functionality over time and the ability to install the meter in any position. The precision of the measurement is not conditioned by the presence of debris and deposits in the measured fluid and the internal lining of the passage tube, either PTFE or EBANITE, allows the management of a wide variety of liquids also chemically aggressive. Remote reading available through GSM/GPRS interface.

Available in separate version with cable connected converter (MAG-S version)

TECHNICAL FEATURES

DIAMETERS AVAILABLE from DN15 to DN2000
AVAILABLE PRESSURESPN10, PN16, PN25, PN40
AVAILABLE PRESSURESUNI EN 1092 ANSI150 ANSI300 DIN2501 BS45404 AWWA
IP PROTECTIONIP68
MAXIMUM READING ERROR ±0,2%
MAXIMUM FLUID SPEED 10 m/s
ELECTRICAL CONDUCTIVITY ≥ 5 μS/cm (powered version), ≥ 20 μS/cm (battey version)
AVAILABLE INTERNAL LININGS PTFE - Ebanite
MAXIMUM FLUID TEMPERATUREMAG-C -40°C /+80°C MAG-S PTFE -40°C /+130°C EBANITE -40°C/+80°C
PIPE MATERIAL Stainless steel AISI 304
FLANGES MATERIALCarbon steel
ELECTRODES MATERIAL Hastelloy C
N° ELECTRODES3(˂DN50), 4(≥DN50)
AVAILABLE POWER SUPPLY 90÷264 VAC or 24 VDC – Replaceable battery 3÷6 years
DISPLAYGraphic LCD 128 x 64 pixels
OUTPUT SIGNALS (powered version) Pulse, 4-20mA frequency, MODBUS, RTU, RS485, Hart protocol
OUTPUT SIGNALS (battery version) Pulse
EXTERNAL COMUNICATION INTERFACE irDA for PC connection , MODBUS RTU, GSM/GPRS
EXTERNAL COMUNICATION INTERFACE ACCORDING TO STANDARDS 89/336/EEC EN61326-1:2006 2006/95/EC EN ISO 6817

INSTALLATION POSITION

WEIGHT AND DIMENSION

DN1520253240506580100125150200250300350400
L200200200200200200200200250250300350450500550600
H223223215221,5224232240246,5259272286311,5338,5364380405