WDC-R

Woltmann type meter with removable insert and magnetic transmission.

Available in sizes from DN50 - 2” to DN200 -8” for hot water up to 130°C.

Approved according to the MID 2004 /22/CE and the EN1434 standard.

Equipped with pulse emitter device it can be connected to the thermal energy calculator mod. HYDROSPLIT-M3

TECHNICAL FEATURES

DN50 (2”)65 (2”1/2)80 (3”)100 (4”)125 (5”)150 (6”)200 (8”)250 (10”)
Overload flow rate Qsm³/h3060901402003005001000
Permanent flow rate Qpm³/h15254060100150250400
Minimum flow rate Qim³/h0,611,62,4461040
Sensibilitym³/h0,250,30,350,61,1248
Minimum readingL0,50,50,50,50,5555
Maximum reading9.999.9999.999.9999.999.9999.999.9999.999.99999.999.99999.999.99999.999.999
Maximum admissible pressure MAPbar1616161616161616
Pulse valueL100100100100100100100100
Range Qp/Qi (H/V)R25R25R25R25R25R25R25R10

BASIC VERSION

  • Accuracy class 3
  • Available for hot water from 0,1°C-130°C
  • Magnetic transmission
  • Direct reading on 6 numeric rolls
  • Dry dial rotating 360°
  • Equipped with pulse emitter device

INSTALLATION POSITION

WEIGHT AND DIMENSION

DN50 (2")65 (2"1/2)80 (3")100 (4")125 (5")150 (6")200 (8")250 (8")
Lmm200200225250250300350450
Hmm728395105120135160193
hmm187197219229257357382427
WeightKg10,311141618,440,551,575,5

Flanges ISO 7005-2 / UNI EN 1092-2 PN10