K-SONIC

- Accurate reading and monitoring thanks to a highly stable ultrasonic measurement over lifetime.
- Very low pressure drop (max 0.16 bar).
- Fast leakage detection.
- High measuring range (R500).
- It can be installed in any position while maintaining the accuracy class.
- Open collector (OC) interface: Integrated 5 contacts.

tekniset ominaisuudet

DN50 (2")65 (2"1/2)80 (3")100 (4")125 (5")150 (6")200 (8")
Overload flow rate Q4m³/h5080801252003132500
Permanent flow rate Q3m³/h406363100160250400
Transitional flow rate Q2L/h1302002003205128001280
Min flow rate Q1L/h80130130200320500800
Starting flowL/h406565100150250400
Max readingm399.999.99999.999.99999.999.99999.999.99999.999.99999.999.99999.999.999
Max admissible pressure MAPbar16161616161616

perusversio

  • R500
  • Battery powered 3.6 VDC Lithium batteries not replaceable
  • Lifetime up to 10 years
  • Available for cold water 0,1°C - 50°C only
  • IP68
  • Predisposed for pulse emitter device mounting: 10L/pulse up to DN125 included, 100L/pulse from DN150 included

asennusasento

TILAUKSESTA

  • Pulse emitter cable 5m / 10m
  • Battery life up to 13 years

PAINO JA MITAT

DN50 (2")65 (2"1/2) 80 (3")100 (4")125 (5")150 (6")200 (8")
Lmm200200225250250300350
Hmm182,5198,5215,5233,5259,5275,5312
H1mm97103108115127134152
Wmm165185200220250285340
L1mm110110110110110110110
WeightKg10121315182536

Flange ISO 7005-2 / EN 1092-2 PN16