GSD8-RFM

Single jet meter, dry dial, direct reading on 8 numerical rolls, with optical predisposition for the installation of M-Bus wired or M-Bus wireless OMS remote reading modules.

With anti-fraud ring and 360° rotating lid. Available in sizes DN15 - 1/2” and DN20 3/4” for both cold water from 0° to 50°C and hot water from 30° to 90°C.

Magnetic transmission

Approved according to MID 2004 /22/CE up to the range R160-H/R50-V

ISO 4064 and OIML R49 compliant

TECHNICAL FEATURES

DN15 (1/2")15 (1/2")20 (3/4")
Overload flow rate Q4m³/h2,003,125
Permanent flow rate Q3m³/h1,62,54
R = 100H ↑Transitional flow rate Q2l/h254064
R = 100H ↑Minimum flow rate Q1l/h162540
R = 160H ↑Transitional flow rate Q2l/h162540
R = 160H ↑Minimum flow rate Q1l/h1015,6325
Minimum readingl0,050,050,05
Maximum reading99.99999.99999.999
Maximum admissible pressure MAPbar161616

BASIC VERSION

  • R100-H ↑ R50-VH→
  • Available for cold water 0°C-50° C and for hot water 30°C-90°C
  • Magnetic transmission
  • Direct reading on 8 numeric rolls
  • 360° rotating dry dial
  • Anti-magnetic fraud protection

INSTALLATION POSITION

UPON REQUEST

  • R160-H ↑ R50-VH→
  • Lid

WEIGHT AND DIMENSION

DN15 (1/2")15 (1/2")15 (1/2")20 (3/4")
Lmm80110115130
Imm160190195228
Hmm73737373
hmm18181818
bmm74747474
D Threadingin3/4"3/4"7/8"-3/4"1"
Weight with unionsKg0,600,650,700,85
Weight without unionsKg0,450,500,550,60

Threading - EN ISO 228-1:2003